Electrical Performances

5.2

 

Electrical Performances

 

5.2.1

DT-X11

 

 

 

Table 5.7

 

 

 

 

 

Item

Specification

Remark

 

Power consumption

DC2.5A/3.7 to 5.0V

 

 

Anti-static strength

 

 

 

 

 

Malfunction

±6 KV

150 pF, 330ohm

 

 

 

Destruction

±12 KV

 

5.2.2 DT-160IOE/DT-169CHGE

Table 5.8

 

Item

Specification

Remark

Current

Approx. 0.1 A

When DT-X11 is not mounted on.

consumption

Approx. 1.6 A

While supplying power or transmitting

 

 

 

data.

Voltage

DC12V±5%

 

Anti-static strength

 

 

 

Malfunction

±6 KV

150 pF, 330 ohm

 

Destruction

±12 KV

 

Power interruption

10 millisec. or less

 

Line noise strength

1,000 V

- Pulse frequency: 5KHz

(Malfunction)

 

- Burst cycle: 300 millisec.

 

 

 

- Number of pulses: 75

 

 

 

- Burst interval: 15 millisec.

5.2.3 DT-167CHGE

Table 5.9

 

Item

 

Specification

Remark

Current

DC 12V

:Approx. 1,400mA

While supplying power.

consumption

DC 24V

: Approx. 700 mA

 

Voltage

DC12V/24V±5%

 

Anti-static strength

 

 

 

 

Malfunction

±6 KV

 

150 pF, 330 ohm

 

Destruction

 

±12 KV

 

 

39