Part V

Parameter List

How to Read the Tables

Number Base Notation

"Size" indicates the parameter value bit width as a decimal value. The bit field position of "Block" as a decimal value.

Values used in the explanations under "Description" are all decimal values, unless specified otherwise. Values other than those described above are all hexadecimal.

R/W Field

The R/W field indicates whether an IPR (Individual Parameter Request) read operation or IPS (Individual Parameter Send) write operation is enabled.

18 System Parameters

These parameters make it possible for an external device to check the status of the Instrument and for an external device to command some operation of the Instrument.

18.1System Information Parameter

This parameter is a container for system information.

Parameter

ID

R/W

Block

Size

Array

Min-Def-Max

Description

Model

0000

R

000000

7

01

00-00-7F

0...reserved

 

 

 

 

 

 

 

1...PX-200/PX-320

 

 

 

 

 

 

 

2...PX-800

 

 

 

 

 

 

 

3...AP-500

 

 

 

 

 

 

 

4...PX-120

Version

0001

R

000000

7

01

00-00-7F

5...PX-720/AP-200

Version Number

Internal Timestamp

0002

R/W

000000

7

10

00-20-7F

Ascii Character

External Timestamp

0003

R/W

000000

7

10

00-20-7F

Ascii Character

33