A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATION INVERTER ARC™ 120

Input Voltages 60 Hz.

INPUT - SINGLE PHASE ONLY

Rated Input Current

120Vac ± 15%

20 Amps @ Rated Output

Duty Cycle

RATED OUTPUT

Output Amps

Output Volts

Input Circuit

20%

70A (Stick)

22.8 Vdc

120 Vac

OUTPUT

Output Current Range

10-90 Amps

Maximum Open Circuit Voltage

72 Volts Max.

Type of Output

DC

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

INPUT VOLTAGE /

TYPE SJT OR HARD USAGE INPUT

MAXIMUM TIME-DELAY CIRCUIT

FREQUENCY (HZ)

CORD

BREAKER OR FUSE SIZE (AMPS)

 

 

 

120/60

3 Conductor, 14 AWG

20

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Length

Weight

7.5 in.

5.0 in.

10.9 in.

Approx. 14.0 lbs.

190.5 mm

127.0 mm

276.9 mm

6.4 kgs.

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-10°C to +40°C

STORAGE TEMPERATURE RANGE

-25°C to +55°C

INVERTER ARC™ 120

Page 10
Image 10
Century IM998 Installation, Technical Specification Inverter ARC, Operating Temperature Range, Storage Temperature Range