CFM Corporation WMC36 WMC42 WMC Series Woodburning Fireplace, Air Space Clearances, Finishing

Models: WMC36 WMC42

1 24
Download 24 pages 11.92 Kb
Page 13
Image 13
Air Space Clearances

adjacent combustible surfaces. (Combustible surfaces include burnable materials such as: ceiling members, joists, flooring, combustible insulation and roof struc- tures.)

WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.

Mark an outline of the roof hole around the center of the point nail. NOTE: Hole dimensions given in the chim- ney top installation instructions are horizontal dimen- sions; therefore, the hole size must be marked on the roof accordingly.

Cover the opening of the installed chimney so debris cannot get into the system.

Cut and frame the hole. It is good practice to use fram- ing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flash- ing anchored to the frame must be able to withstand

WMC Series Woodburning Fireplace

Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).

1¹⁄" (SK8)

 

2" (3-wall)

Standoff

 

¹⁄" Air Space To Sides

Front View

Side View

heavy winds.

Install Remainder of Chimney Sections

Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height.

Check the chimney top installation instructions for details on how high above the roof top the chimney sec- tions (all pipes) should extend.

Installing Top Housing

or Termination

Follow the installation instructions provided with the chimney termination you have selected.

Installing Chimney In a Chase

Refer to Page 4, Figure 3 for an illustration of a typical chase installation.

CAUTION: Treatment of firestop spacers and con- struction of chase may vary with type of building.

Wall

Shield

Only noncombustible material may be applied as facing to the black fireplace surround.

Install Remainder of Chimney Sections Firestop

¹⁄" Air Space to Back

¹⁄" Air Space to Sides

Installing Top Housing 0" Clearance to Floor

Hearth

Extension FPC559

These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTE: Other building materials may be required in addition to Firestop Spacers.

Finishing

CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with noncombustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 21)

Fig. 21 Minimum clearances to combustibles.

Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305 mm) from top of grille opening. Do not install a mantel face plate less than 6" (159 mm) from top of grille opening. (Fig. 23) If a combustible material is used below a flat mantel shelf, consult your local build- ing codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.

All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figs. 22 and 23)

20000583

13

Page 13
Image 13
CFM Corporation WMC36 WMC42 WMC Series Woodburning Fireplace, Air Space Clearances, Install Remainder of Chimney Sections