Chimney Supports
The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6
m)with
Angled chimney runs require a support every 6' (1.8m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 7)
Chase Installation
A chase is a vertical boxlike structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 3)
If you need help in determining fireplace location or how the chimney system should be run, contact your
CFM Corporation dealer for assistance.
Chimney Sup- port Strap
Chimney
Support
FP284
Fig. 7 Chimney support installation.
WMC Series Woodburning Fireplace
Installation
Insulating Fireplace Enclosure
for Cold Climates
If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 8)
When a fireplace is installed in a chase or on a outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 3)
When installing the chimney, DO NOT caulk between outer pipe and firestop. It is vital that some air be al- lowed to flow through this very thin gap.
CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE ALL RE- QUIRED AIR SPACES ARE MAINTAINED. (Page 13,
Fig. 18)
Cover Plate
Top Shield
Hard, Flat
Surface
Insulation
PlatformFPC555
Fig. 8 Insulating between platform and fireplace.
20000583 | 7 |