4 AFE-T-BEAM®SYSTEM INSTALLATION

WARNING

There should be no electrical power to the opener while installing Safe-T-Beam®wires. If you have plugged in the power cord—UNPLUG IT NOW!

NOTE: The opener will not close the door automatically unless the Safe-T-Beam®System is installed.

NOTE: For Safe-T-Beam®, screws, wire, and insulated staples locate items and Bag 8 from Box 3.

1. Mounting brackets.

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

mark

FIG. 4-1 Mark door frame.

‡ Mark both sides of garage door frame or wall no

higher than 6" and no lower than 5" above floor

(Fig. 4-1).

‡ Hold bracket against door frame or wall.

– Check if brackets extend out from wall far

enough, so tongue of bracket is beyond door,

tracks or any door hardware.

– If not:

a)

Mounting bracket extensions are available

b)

through an authorized Genie® Dealer.

Blocks of wood, etc. may be substituted for

 

extensions.

‡ Center bracket on your mark (Fig. 4-2).

‡ Fasten each with 2 screws (Fig. 4-2).

NOTE: Mounting brackets can be attached to the floor or concrete rim using concrete anchors (not provided).

center of

bracket

FIG. 4-2

Mounting brackets.

SUN

 

e

 

lid

 

s

 

bracket

 

tongue

FIG. 4-3

Attach

Safe-T-Beam® to brackets.

2.Mounting Safe-T-Beam®Source (Red LED) and Sensor (Green LED).

‡If garage has only one garage door.

Determine which side of garage receives most direct sunlight (Fig. 4-4).

Red LED should always be on sunny side whenever possible (Fig. 4-4).

‡For multiple doors.

Preventing crossed signals is critical.

Place source and sensor modules on adjacent doors facing in opposite directions (Fig. 4-4).

NOTE: To help prevent interference from sun, Safe-T-Beam®sensor with Green LED may be placed further away from the door opening, though extended no further out from the wall, where it will spend more time in shadow.

‡Slide source/sensor onto tongue of bracket until it clicks into place (Fig. 4-3).

3a. Wiring (If NOT pre-wired).

‡ Route wire from Safe-T-Beam®to power head using method shown in (Fig. 4-5a).

‡ Securely fasten wires to wall and ceiling as you go (Fig. 4-6 on next page).

– Use insulated staples.

– Staples should be snug only.

Insulated

Staple

RED

GREEN

GREEN

RED RED

GREEN

LED

LED

LED

LED LED

LED

ONE DOOR

 

TWO DOOR

 

 

GARAGE

 

GARAGE

 

 

GREEN

RED RED

GREEN GREEN

RED

LED

LED LED

LED

LED

LED

THREE DOOR

GARAGE

FIG. 4-4 Safe-T-Beam®source and sensor locations.

Red

Green

Source

Sensor

 

 

 

 

 

 

or

 

 

 

 

 

 

 

6 5 4 3 2 1

6 5 4 3 2 1

 

 

 

 

 

 

 

 

 

Dashed Line = striped wire

 

Power

 

Head

 

 

 

Solid Line = white wire

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 4-5a Source and sensor wiring methods.

PN# 3642036534, 02/26/2010 REV. 1

17

 

Page 17
Image 17