Chamberlain 1024, 1042, 1022 manual Onnecting to Power, With Permanent Wiring, With Power Supplied

Models: 1022 1024 1042

1 30
Download 30 pages 40.04 Kb
Page 19
Image 19

5 ONNECTING TO POWER

WARNING

‡To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door opener must be properly grounded in order to prevent personal injury and damage to the components.

‡DO NOT remove motor cover. All work performed on motor must be done by a trained door system technician.

CAUTION

‡Check local building codes to make sure that you are not required to have your garage door opener permanently wired, with circuit breaker protection. If building codes require door opener to be permanently wired have a qualified licensed electrician connect power with permanent wiring.

WITH GROUNDED PLUG:

Plug the opener into a properly grounded electrical outlet (Fig. 5-1).

WITH PERMANENT WIRING:

Instructions for Electrician.

‡Remove power from circuit.

‡Remove rear cover and motor cover.

Remove four motor cover screws (Fig. 5-2).

‡Remove existing power cord and strain relief from the 7/8" dia. hole and discard (Fig. 5-3).

‡Connect permanent wiring to power head using 7/8" diameter hole.

White to white/black to black/ground to green.

Use only UL recognized wire nuts.

‡Wires inside the power head must be at least 6" in length.

‡Replace motor cover and rear cover and re-energize the circuit.

NOTE: The Genie Company is not responsible for charges resulting from work preformed by an independent electrician.

WITH POWER SUPPLIED:

Check Safe-T-Beam®alignment (Fig. 5-4).

‡Insure that no part of door or its hardware is in path between lenses of source and sensor.

‡Insure that tops of lenses are between 5" - 6" above the floor (Fig. 5-4). The brackets are flexible, and can be adjusted slightly if needed.

‡Adjust the Red LED source by aiming the unit directly at the Green LED sensor. Use the adjustment screw located on the top of the source housing to make adjustments.

‡The Red LED source will blink if there is a misalignment. When the LED units are aligned the Red LED will remain ON continuously.

‡After the alignment is finished tighten the adjustment screws on Safe-T-Beam®.

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

FIG. 5-1 Connect to power.

Motor Cover Screws

FIG. 5-2 Remove motor cover.

FIG. 5-3 Power cord strain relief.

CAUTION

‡Do NOT use an extension cord.

‡Do NOT use a portable generator. This product is designed to operate using standard household current.

‡Do NOT use alternate power supplies.

 

 

 

 

o

m

fl

o

o

r

 

 

ax

fr

 

r

 

 

 

 

 

 

 

 

 

6"

m

om

fl

oo

 

 

 

 

 

5"

min

fr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 5-4 Check Safe-T-Beam®alignment.

INFRARED PROTECTION FUNCTION

1.When the garage door is opening, its movement will not be influenced if the Safe-T-Beam®is obstructed.

2.If the Safe-T-Beam®is obstructed before the garage door fully closes, the door will not close.

3.When the garage door is closing, if Safe-T-Beam®is cut off by people or obstacle, the garage door will reverse automatically to its fully opened position. (Meanwhile, the opener light will keep blinking until door moves to its fully opened position.)

4.If the Safe-T-Beam®System fails, loses power, or is installed improperly, you will have to press and hold the wall control "close" button until the door reaches its fully closed position. The LED indicator light on the power head will be green and blink twice (Pattern: ☼☼ pause ☼☼ pause) to inform you to eliminate problem first. Otherwise, the door will reverse automatically to its fully opened position if you release the "close" button on the wall control during the closing movement.

PN# 3642036534, 02/26/2010 REV. 1

19

 

Page 19
Image 19
Chamberlain 1024, 1042, 1022 manual Onnecting to Power, With Permanent Wiring, With Power Supplied