![](/images/backgrounds/52254/52254-105x1.png)
Adjustment
STEP 3 Test Safety Reverse System
THE SAFETY REVERSE SYSTEM TEST IS IMPORTANT. GARAGE DOOR MUST REVERSE ON CONTACT WITH A ONE INCH OBSTACLE PLACED ON THE FLOOR. FAILURE TO PROPERLY ADJUST OPENER MAY RESULT IN SERIOUS PERSONAL INJURY FROM A CLOSING GARAGE DOOR. REPEAT TEST AT LEAST FOUR TIMES A YEAR AND ADJUST AS NEEDED..
PROCEDURE: Place a
If a the door STOPS on the obstruction, it is not traveling far enough in the DOWN direction. Increase the DOWN limit by turning DOWN limit adjustment screw counterclockwise 1/4 turn.
REPEAT TEST.
NOTE: Make sure limit adjustments do not force the door arm beyond a straight up and down position. See the illustration on Page 13.
When the door reverses on the
REPEAT ADJUSTMENT STEP 3 AFTER:
•EACH ADJUSTMENT OF DOOR ARM LENGTH, CLOSE FORCE OR DOWN LIMIT.
•ANY REPAIR OR ADJUSTMENT OF GARAGE DOOR (INCLUDING SPRINGS AND HARDWARE).
•ANY REPAIR OR BUCKLING OF THE GARAGE FLOOR.
•ANY REPAIR OR ADJUSTMENT OF THE GARAGE DOOR OPENER.
(Optional) | STEP 4 Install the Protector System |
|
|
The PROTECTOR SYSTEM™ provides an ADDITIONAL measure of safety against a small child being caught under a garage door. It uses an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing.
After the garage door opener has been completely installed and adjusted, the PROTECTOR SYSTEM™ accessory can be installed. Instructions are included with this optional device.
18