INSTALLATION STEP 5

Install the Door Control

Locate door control within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1).

NOTE: The functional temperature range of the door control is between -20°C (-4°F) and +50°C (+122°F). Scroll speed of display is slower at lower temperatures although the door control remains fully functional.

CAUTION: Continuous exposure of the door control to temperatures below -22°F (-30°C) may damage the LCD screen.

SPECIAL NOTE: Only one 398LM can be connected to each garage door opener. If additional wall controls are desired to operate the same garage door opener, it is recommended to use model 378LM wireless wall control as the secondary door control.

To prevent possible SERIOUS INJURY or DEATH from electrocution:

Be sure power is not connected BEFORE installing door control.

Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m) and away from ALL moving parts of door.

NEVER permit children to operate or play with door control push buttons or remote controls.

Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.

ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

HARDWARE SHOWN ACTUAL SIZE

1. Strip 7/16" (11 mm) of insulation from one end of bell

wire and connect to the two screw terminals on back of

door control by color: white wire to the W (2) and

white/red wire to the R (1) (Figure 2).

2. Remove push bar cover by gently prying at the

lower/middle portion of the cover with a small flat-head

screwdriver. Fasten with 6AB x 1-1/4" self-tapping

screws (drywall installation) or 6-32 x 1" machine

screws (into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to protrude

above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid cracking

plastic housing. Do NOT overtighten.

Screw 6ABx1-1/4" (standard installation)

Screw 6-32x1" (pre-wired)

REMOVE & REPLACE COVER

To Replace Insert

Top Tabs First

Push Bar Cover

LOC

K

LIGHT

 

Figure 1

Insulated

Staples

Drywall Anchors

PRE-WIRED INSTALLATION

LOCK

24 Volt Bell Wire

 

LIGHT

• Replace cover by inserting top tabs first and then snap

cover in place.

3. (For standard installations ONLY) Run bell wire up

wall and across ceiling to motor unit. Use insulated

staples to secure wire in several places. Do NOT pierce

wire with a staple, creating a short or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals on the

2-Conductor

 

Push Bar

Bell Wire

 

 

 

 

 

Door

 

 

 

Control

 

 

 

Terminal

 

R

W

Screws

 

1

2

LOCK

 

 

 

Lock

LOCK

 

 

 

(BACK VIEW)

Button Light

motor unit: white to white and white/red to red

(Figure 3).

Figure 2

Button

NOTE: DO NOT connect the power and operate the opener at this time. The door will travel to the full open position but will not return to the close position until the sensor beams are connected and properly aligned. See page 14.

7/16" (11 mm)

Strip wire 7/16" (11 mm)

10

Door Control

Connections

Figure 3

WHT/RED

WHT

To insert or release wire, push in tab with screwdriver tip