Troubleshooting (continued)

Problem

Possible Cause

Prevention/Solution

 

 

 

Burner(s) will not light

ELECTRONIC IGNITION:

• See Section I of Electronic Ignition System.

using ignitor.

• No spark, no ignition noise.

(See Electronic Ignition

• No spark, some ignition noise.

• See Section II of Electronic Ignition System.

Troubleshooting also)

 

• Sparks, but not at electrode or at full

• See Section III of Electronic Ignition System.

 

strength.

 

Burner(s) will not

• See “GAS ISSUES:” on previous page.

 

match light.

• Match will not reach.

• Use long-stem match (fireplace match).

 

 

• Improper method of match-lighting.

• See “Match-Lighting” section of Use and Care.

Sudden drop in gas

• Out of gas.

• Check for gas in LP cylinder.

flow or low flame.

• Excess flow valve tripped.

• Turn off knobs, wait 30 seconds and light grill. If flames are still low,

 

 

 

turn off knobs and LP cylinder valve. Disconnect regulator.

 

 

Reconnect regulator and leak-test. Turn on LP cylinder valve, wait

 

 

30 seconds and then light grill.

 

• Vapor lock at coupling nut/LP cylinder

• Turn off knobs and LP cylinder valve. Disconnect coupling nut from

 

connection.

cylinder. Reconnect and retry.

Flames blow out.

• High or gusting winds.

• Turn front of grill to face wind or increase flame height.

 

• Low on LP gas.

• Refill LP cylinder.

 

• Excess flow valve tripped.

• Refer to “Sudden drop in gas flow” above.

Flare-up.

• Grease buildup.

• Clean burners and inside of grill/firebox.

 

• Excessive fat in meat.

• Trim fat from meat before grilling.

 

• Excessive cooking temperature.

• Adjust (lower) temperature accordingly.

 

 

 

Persistent grease fire.

• Grease trapped by food buildup around

• Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in position

 

burner system.

and let fire burn out. After grill cools, remove and clean all parts.

 

 

 

Flashback...

• Burner and/or burner tubes are blocked.

• Turn knobs to OFF. Clean burner and/or burner tubes. See burner

(fire in burner tube(s)).

 

cleaning section of Use and Care.

Unable to fill LP

• Some dealers have older fill nozzles

• The worn nozzles don’t have enough “bite” to engage the valve. Try

cylinder.

with worn threads.

a second LP dealer.

One burner does not

• Grease buildup or food particles in

• Clean carry-over tube(s) with wire brush.

light from other

end(s) of carryover tube(s).

 

burner(s).

 

 

AUTO-CLEAN™

Possible Cause

Prevention/Solution

(If Equipped)

 

 

Timer does not work

ŸDead Battery

ŸReplace Batteries

(Green light does not

ŸBatteries installed incorrectly.

ŸInstall batteries correctly.

flash)

ŸKnob Position did not start the Clean

ŸPush Knob in to start the clean cycle. (Green LED should begin to

 

Cycle

flash)

 

 

 

No LED’s will illuminate

ŸDead Battery

ŸReplace Batteries

 

 

 

Red LED next to battery

ŸLow Battery Strength

ŸPrepare to replace batteries (NOTE: Clean cycle will operate with

symbol is illuminated

 

a weak battery.

 

 

 

24

Page 24
Image 24
Char-Broil 463210011 manual Auto-Clean