Troubleshooting (continued)
Problem | Possible Cause | Prevention/Solution | |
|
|
| |
Burner(s) will not light | ELECTRONIC IGNITION: |
| |
using ignitor. | • No spark, no ignition noise. | • See Section I of Electronic Ignition System. | |
(See Electronic Ignition |
|
| |
Troubleshooting also) | • No spark, some ignition noise. | • See Section II of Electronic Ignition System. | |
| • Sparks, but not at electrode or at full | • See Section III of Electronic Ignition System. | |
| strength. |
| |
| PIEZO |
| |
| • | • Replace ignitor. | |
| • Rotary knob rotates without clicking. | • Replace knob. | |
| • Sparking between ignitor and electrode. | • Inspect wire insulation and proper connection. Replace wires if | |
|
| insulation is broken. | |
|
|
| |
Burner(s) will not | • See “GAS ISSUES:” on previous page. |
| |
match light. |
|
| |
| • Match will not reach. | • Use paper match, | |
|
| holder (where supplied). | |
| • Improper method of |
| |
|
| • See | |
|
|
| |
Sudden drop in gas | • Out of gas. | • Check for gas in LP tank. | |
flow or low flame. |
|
| |
| • Excess flow valve tripped. | • Turn off knobs, wait 30 seconds and light grill. If flames are still low, | |
|
| turn off knobs and LP tank valve. Disconnect regulator. Reconnect | |
|
| regulator and | |
|
| then light grill. | |
| • Vapor lock at coupling nut/LP tank | • Turn off knobs and LP tank valve. Disconnect coupling nut from | |
| connection. | tank. Reconnect and retry. | |
|
|
| |
Flames blow out. | • High or gusting winds. | • Turn front of grill to face wind or increase flame height. | |
| • Low on LP gas. | • Refill LP tank. | |
| • Excess flow valve tripped. | • Refer to “Sudden drop in gas flow” above. | |
|
|
| |
• Grease buildup. | • Clean burners and inside of grill/firebox. | ||
| • Excessive fat in meat. | • Trim fat from meat before grilling. | |
| • Excessive cooking temperature. | • Adjust (lower) temperature accordingly. | |
|
|
| |
Persistent grease fire. | • Grease trapped by food buildup around | • Turn knobs to OFF. Turn gas off at LP tank. Leave lid in position and | |
| burner system. | let fire burn out. After grill cools, remove and clean all parts. | |
|
|
| |
Flashback... | • Burner and/or burner tubes are blocked. | • Turn knobs to OFF. Clean burner and/or burner tubes. See burner | |
(fire in burner tube(s)). |
| cleaning section of Use and Care manual. | |
|
|
| |
Unable to fill LP tank. | • Some dealers have older fill nozzles | • The worn nozzles don’t have enough “bite” to engage the valve. Try | |
| with worn threads. | a second LP dealer. | |
|
|
| |
One burner does not | • Grease buildup or food particles in | • Clean | |
light from other | |||
end(s) of carryover tube(s). |
| ||
burner(s). |
| ||
|
|
25