3.SETUP
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
Fuse Replacement
With a
Data Linking
The fuse is located inside this compartment. Remove using a flat head screwdriver.
You will need a serial data link to run light shows of one or more fixtures using a
Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase
CAUTION | Do not allow contact between the common and the fixture’s chassis ground. Grounding the common |
| can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to |
| verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. |
Master/Slave Linking
1.Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture.
2.Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for
Slave |
Slave |
Master |