Electrical Precautions:

Electrical Precautions:

1.All connections and conduits from the Generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.

2.The Generator must be properly earth-grounded by a licensed electrician in accordance with all relevant electrical codes and standards before operation.

3.If an extension cord (not included) is used, make sure to use only UL® approved cords having the correct gauge and length. (See Figure A.)

FIGURE A

REQUIRED MINIMUM EXTENSION CORD GAUGE – 120/ 240 VOLT

NAMEPLATE

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

(At Full Load)

 

 

 

 

 

 

 

0 - 25

25 - 50

50 -100

100 – 150

150– 200

 

 

Feet

Feet

Feet

Feet

Feet

0 - 5

16

16

16

12

12

5.1

- 8

16

16

14

10

-

8.1 - 12

14

14

12

-

-

12.1

- 15

12

12

10

-

-

15.1

- 20

10

10

10

-

-

SKU 90236

For technical questions, please call 1-800-444-3353.