NOISE PRECAUTION

NOISE PRECAUTION

Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the Generator when it is running.

ELECTRICAL PRECAUTIONS

1.All connections and conduits from the Generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.

2.The Generator must be earth-grounded in accordance with all relevant electri- cal codes and standards before operation.

3.If an extension cord (not included) is used, make sure to use only UL listed cords having the correct gauge and length. (See TABLE A)

REQUIRED MINIMUM EXTENSION CORD GAUGE - 120 VOLT

NAMEPLATE

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

(at full load)

 

 

 

 

 

0-25 Feet

25-50 Feet

50-100 Feet

100-150 Feet

150-200 Feet

 

 

 

 

 

 

 

 

0 – 5

16

16

16

12

12

5.1

– 8

16

16

14

10

-

8.1 – 12

14

14

12

-

-

12.1

– 15

12

12

10

-

-

15.1

– 20

10

10

10

-

-

TABLE A

4.Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground.

5.Do not touch electrically energized parts of the Generator and interconnect- ing cables or conductors with any part of the body, or with any non-insulated conductive object.

6.Connect the Generator only to a load or electrical system (115 volt) that is compatible with the electrical characteristics and rated capacities of the Generator.

7.Before servicing equipment powered by the Generator, disconnect the equip- ment from its power input.

SKU 98452

For technical questions, please call 1-800-444-3353.