INSTALLATION

Installation Instructions

PAC 510, 515, 520

INSTALLATION

The PAC-510 is intended for use in installations where an existing finshed (drywalled) wall is present, and includes flanged edges to cover the cutout in wall. The PAC-515 and PAC-520 are intended for use in installations where the wall surface has not been finished and the structure (studs) is exposed. The PAC-515, and PAC-520 require the wall be finished around the opening of the box after the box has been installed.

WARNING: IMPROPER INSTALLATION CAN RESULT DEATH OR SERIOUS PERSONAL INJURY! This accessory should be installed by qualified personnel.

PAC-510 Site Preparation

Locate and Prepare Mounting Site

1.Identify a suitable wall location for the accessory.

IMPORTANT ! : The PAC-510, 515, AND 520 are designed for in-wall installation between two wood or steel studs, 16" on center. Inadequate space will remain on each side between studs for electrical wires/cables, plumbing, ductwork, or insulation. Locate accordingly!

WARNING: ELECTRICAL SHOCK HAZARD! CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind

mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.

WARNING: EXPLOSION AND FIRE HAZARD! CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surfaces is free of gas, water, waste, or any other plumbing before cutting, drilling, or installing fasteners.

2.Using a stud sensor, locate and mark studs.

3.Center and level housing between marked studs.

4.Using housing as a template, draw pencil line completely around housing.

NOTE: Housing is designed to fit between and directly against two adjacent wall studs.

5.Using a measuring tool, measure the marked area and compare to the dimensions shown in figure1 below. If measurements match continue to step 6 if not adjust markings to match dimensions in figure 1 below.

6.Cut drywall on outside edge of line and remove.

Figure 1

5

Page 5
Image 5
Chief Manufacturing PAC510 PAC-510 Site Preparation, Installation Instructions, Pac, Locate and Prepare Mounting Site