MAINTENANCE
ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property dam- age. Heater must be installed or serviced by a qualified person in accordance with the National Electrical Code, NFPA 70.
To Remove Heating Element
1. Remove terminal cover screws 13 and terminal cover 3 at ter- minal end of heater.
2.Disconnect heating element from electrical leads at both ends.
3.Remove screws 12 and nuts 10 from porcelain terminal blocks 9 and 11 .
4.Remove element support clips 7 and 15 and secondary insula- tion bushings.
5.Lift element out of heater.
To Install Element
Observe instructions for removing element and proceed in reverse order. Be sure to replace secondary insulation bushings.
Care of Reflectors
Reflectors should be cleaned periodically. A mild soap and water solution or fine cleaning powder is best although more drastic means may be required if reflectors are badly soiled by chemical or other deposits. The reflector is aluminum. DO NOT use alkali cleaners since alkalies will dull reflector. Mild non- alkaline cleaners, such as used for scouring kitchen sinks, may be used. Reflectors are replaceable and may be purchased from Chromalox.
RENEWAL PARTS IDENTIFICATION
|
| Number |
| 1 | 2 | 6 | 7 | 15 | |
|
| of | kW Per | Element | Reflector | Insulation | Element | Bushing | |
Model | Volts | Elements | Element | Model No. | Sheet | Bushing | Support Clip | Retaining Clip | |
208 or 275 | 3 |
| |||||||
240 or 480 |
| ||||||||
|
| 4.4 |
|
|
|
| |||
|
|
|
|
|
|
|
| ||
208 or 275 | 6 | ||||||||
| |||||||||
240 or 480 |
| ||||||||
|
|
|
|
|
|
| |||
208 or 275 | 3 |
| |||||||
240 or 480 |
| ||||||||
|
| 6.0 |
|
|
|
| |||
208 or 275 | 6 | ||||||||
| |||||||||
240 or 480 |
| ||||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
NOTE: Part numbers suffixed by a number in ( ) indicates the quantity of the same part number used
3