Caveats
Resolved Caveats in Previous Versions
These problems were resolved in version 9.00.05:
•CSCds09069
Catalyst 1900 and 2820 switches can now communicate with other management VLANs even if the switch has no ARP entry in its ARP table for a default gateway or does not have a port assigned to a management VLAN.
•CSCds60075
The MIB object IfLastChange now reports the correct time when the LinkUp/LinkDown Traps are disabled on the switch.
•CSCdt65828
The FDDI DAS module no longer incorrectly appears as an SAS module in a Catalyst 2820 switch.
•CSCdr56930
The show cdp neighbor detail command now works correctly on the switch and no longer shows only the IP address of the command switch.
•CSCds57774
The switch no longer fails when the HTTP server is enabled and a browser tries to access the URL
•CSCds77252
Catalyst 1900 and 2820 switches running Enterprise software release 9.00.05 can now answer queries for the MIB object ipAdEntNetMask when you use the snmpget command.
•CSCdt33416
SNMP operations with null community strings are no longer allowed.
•CSCdv09114
If a switch is installed before the DHCP scope is configured on the DHCP server, or before the DHCP server is online the switch now completes automatic configuration through TFTP.
•CSCdv11505
Catalyst 1900 and 2820 switches now respond to ARP requests in a redundant uplink configuration where there are no access ports assigned to the management VLAN.
•CSCdv35159
Catalyst 1900 and 2820 switches no longer allow community strings ending with a numeral or an @ symbol.
•CSCdu56824
Catalyst 1900 and 2820 switches no longer allow privileged EXEC access with a user EXEC password.
Release Notes for the Catalyst 1900 and Catalyst 2820 Series Switches, Version 9.00.06