4
Release Notes for CPE/CS3 Switch Software Release 2.2.0.3
78-10367-01
Caveats
Resolved Caveats—Release 2.2.0.1
The following bugs that existed in Release 2.1.0.6 were fixed and verified in Release 2.2.0.1.
Open Caveats—Release 2.2.0.1
Cisco MGX 8240 CPE/CS3 Switch software (Release 2.2.0.1) has some known problems. Every
attempt has been made to address and resolve the problems of high severity. Below are the lists of
knownbugs that exist in the Cisco MGX 8240 system, including all outstanding problems related to the
CES modules and associated I/O ports. The second column is the defect severity. A number 0
represents the greatest severity, while 5 is the least severe.
DDTS Number SeveritySeveSrit
y
Functional
Area Problem
Description Corrected
Dm77697 2 Mfg record Switch
manufacturing
record is not
available for
reading.
Mfg record is
now reported. Fixed
Dm77794 2 Statistics The SONET
FarEnd Line 24Hr
UASThreshold can
not be set.
Willbe fixed in
FCS release. Defaulted
to 10 secs
DDTS
Number Severity
SeveSrity
Functional
Area Problem
Description Corrected
Sn04840 1 Switch
Shaping Policing on
Ascend 550
causes inband
cells to be
dropped
because
Maximum
Burst
Size(MBS) is
not
configurable
and fixed to
1024 cells.
Do not turn on policing
at Ascend, or set it to
1024 cells.
Same as
1.1.1.2
Sn04752 3 Switch Craft
Interface Double ESC
requiredto exit
from DS1
statistics
window on
Craft Interface.
Same as
1.1.1.2