7
Release Notes for CPE/CS3 Switch Software Release 2.2.0.3
78-10367-01
Related Documentation
Related Documentation

Hardware Documents

Cisco MGX 8240 Hardware Installation Guide, DOC-7810084=. Gives information on installing the
MGX 8240, including physical connectivity, logical connectivity, and cabling.
Cisco MGX 8240 Hardware User’s Guide, DOC-7810083=. Gives theory of operations and usage
information on the MGX 8240. Details physical description, traffic management, and FDOS.

Software Document

Cisco MGX 8240 VCLI User’s Guide, DOC-7810082=. Gives information on installation and use of
Virtual Command Line Interface (V-CLI) for MGX 8240.Details installation, provisioning, and
specific commands for VCLI.
Sn05203 2 BERT Circuit will not pass data if
it is created while DS1s on
both ends of a local circuit
are under BERT.
Workaround: delete
and create the circuit
again after BERT is
stopped.
Same as
1.1.2.10
Sn05554 1 FE
Loopback If the user manipulates the
far-end DS1 loop modes
more rapidly than the 1.5
second (the loop send code
duration time), the far-end
Larscom CSU/DSU and the
Cisco MGX 8240 DS1 port
are both in a loop up mode.
Once this happens, the loop
downcommand issued from
NMS is unable to take
Larscom CSU/DSU out of a
loop.
Workaround:
1. On NMS go to
the port's Near
End Loopback.
Invoke a Near
End Loopback,
then drop the
loop.
2. Go to the Far
End Loopback
and invoke the
loop first and
then drop it.
Bug found
in 1.1.2.10
Dm61874 2 Port State When using OC3 IO, STS
Path LOP and Label
Mismatch will not
automatically show a
problem in the contained
DS3 state.
Workaround:Look at
OC3 state as well as
DS3 state when using
OC3 IO.
Dm77697 2 Mfgrecord Switch manufacturing
record is not available for
reading.
Will be fixed in FCS
release. Currently
returns
blank
Dm77794 2 Statistics SONET FarEnd Line 24Hr
UAS Threshold cannot be
set.
Will be fixed in FCS
release. Defaulted
to 10secs