5
Release Notes for CPE/CS3 Switch Software Release 2.2.0.3
78-10367-01
Caveats
Sn05174 0 Xyplex FTP failed
sometimes due
to Xyplex’s
problem.
Pending on Xyplex new
fix. Same as
1.1.1.11
Sn05203 2 BERT Circuitwill not
passdata if it is
created while
DS1s on both
ends of a local
circuit are
under BERT.
Workaround:Delete and
create the circuit again
after the BERT is
stopped.
Same as
1.1.1.11
Sn05554 1 FE Loopback If the user
manipulates
the far-end
DS1 loop
modes more
rapidly than
the 1.5 second
(the loop send
code duration
time), the
far-end
Larscom
CSU/DSU and
the Cisco
MGX 8240
DS1 port are
both in a loop
up mode. Once
this happens,
the loop down
command
issued from
Sentient NMS
is unable to
take Larscom
CSU/DSU out
of a loop.
Workaround:
1. On NMS go to the
port's Near End
Loopback. Invokea
Near End
Loopback, then
drop the loop.
2. Go to the Far End
Loopback and
invokethe loop first
and then drop it.
Bug found in
1.1.2.10