Installing the SP Bootflash Memory Upgrade Kit
To upgrade your SP ROMMON, perform these steps:
Step 1 Download the latest SP ROMMON
Step 2 Display the SP ROMMON image status by entering the show
Note The system responds with a message indicating that SP is: “Currently running ROMMON from the S (Gold) region.”
Step 3 Verify that the necessary SP ROMMON version is present by entering the dir
Step 4 Upgrade the SP ROMMON image by entering the upgrade
Note Slot 5 indicates the slot number of the supervisor engine to be upgraded; the supervisor engine can be installed in either slot 5, slot 6, or in both slots.
Reload the switch by entering the reload command. At the prompt, type Y to confirm and press Enter.
Note Do not perform a Reset.
Step 5 Boot the Cisco IOS software from the boot device. At this point the SP ROMMON upgrade process is complete; the next steps are used to verify that the upgrade has been completed correctly.
Step 6 Enter privileged EXEC mode by entering the enable command
Step 7 Display the SP ROMMON image status by entering the show
Note The system responds with a message indicating that SP is “Currently running ROMMON from F1 region.”
Step 8 Verify the SP ROMMON version by entering the remote command switch show version include ROM command.
Note You should see “ROM: System Bootstrap, Version 8.4(2).”
Cisco CompactFlash Adapter for Bootflash Upgrade Installation Note
| 9 |
| |
|
|