Cisco Systems MEM-MSFC2-512MB=, MEM-S2-512MB=, MEM-S3-1GB= f. Verify that the STATUS LED is lit

Models: MEM-MSFC3-1GB= MEM-S3-1GB= MEM-S2-512MB= MEM-MSFC2-512MB=

1 32
Download 32 pages 27.66 Kb
Page 16
Image 16
f.Verify that the STATUS LED is lit.

Installing the SP and RP Memory Upgrade Kit

Step 3 Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the following two sets of stepsfor positioning the module in a chassis with either horizontal or vertical slots:

Horizontal slots

a.Position the supervisor engine in the slot. (See Figure 6.) Make sure that you align the sides of the module carrier with the slot guides on each side of the slot.

b.Carefully slide the supervisor engine into the slot until the EMI gasket along the top edge of the module makes contact with the module in the slot above it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate. (See Figure 7.)

c.Using the thumb and forefinger of each hand, grasp the two ejector levers, and press down to create a small 0.040 inch (1 mm) gap between the supervisor engine’s EMI gasket and the module above it. (See Figure 7.)

Note Do not press down too forcefully on the levers because they will bend and become damaged.

d.While pressing down, simultaneously close the left and right ejector levers to fully seat the supervisor engine in the backplane connector. The ejector levers are fully closed when they are flush with the module faceplate. (See Figure 7.)

Note Failure to fully seat the module in the backplane connector can result in error messages.

e.Tighten the two captive installation screws on the supervisor engine.

Note Make sure that the ejector levers are fully closed before tightening the captive installation screws.

f.Verify that the STATUS LED is lit.

Periodically check the STATUS LED. If the STATUS LED changes from orange to green, the module has successfully completed the boot process and is now online.

If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and may have encountered an error.

Supervisor Engine 720 Switch Processor and Route Processor Memory Installation Note

16

78-15538-02

 

 

Page 16
Image 16
Cisco Systems MEM-MSFC2-512MB=, MEM-S2-512MB=, MEM-S3-1GB=, MEM-MSFC3-1GB= manual f. Verify that the STATUS LED is lit