C-28
Cisco IOS Software Configuration Guide for Cisco Aironet Access Points
OL-30644-01
AppendixC Error and Event Messages
Sensor Messages
Sensor Messages
Error Message SENSOR-3-TEMP_CRITICAL: System sensor “d” has exceeded CRITCAL
temperature thresholds
Explanation One of the measured environmental test points exceeds the extreme threshold.
Recommended Action Correct the specified condition, or the system may shut itself down as a
preventive measure. Enter the show environment all to help determine if this is due to temperature
or volatage condition. If this is a critical temperature warning, please ensure that the router fans are
are operating and that the room cooling and air-conditioning are functioning. This condition could
cause the system to fail to operate properly.
Error Message SENSOR-3-TEMP_NORMAL: “s” temperature sensor is now normal
Explanation One of the measured environmental test points is under normal operating temperature.
Recommended Action None.
Error Message SENSOR-3-TEMP_SHUTDOWN: Shuting down the system because of dangerously
HIGH temperature at sensor “d”.
Explanation One of the measured environmental test points exceeds the operating temperature
environment of the router.
Recommended Action Investigate the cause of the high temperature.
Error Message SENSOR-3-TEMP_WARNING: “s” temparature sensor “d” has exceeded WARNING
temperature thresholds
Explanation One of the measured environmental test points exceeds the warning threshold.
Recommended Action Closely monitor the condition and correct if possible, by cooling the
environment.
Error Message SENSOR-3-VOLT_CRITICAL: System sensor “d” has exceeded CRITCAL voltage
thresholds
Explanation One of the measured environmental test points exceeds the extreme voltage threshold.
Recommended Action Correct the specified condition, or the system may shut itself down as a
preventive measure. Enter the show environment all to help determine if this is due to volatage
condition. This condition could cause the system to fail to operate properly.