100
To view FRU errors on your Topspin 270, enter the show diagnostic fru-error command.
Example
Error Types
The following types of hardware errors are logged for the Topspin 270 baseboard:
The following types of hardware errors are logged for the Topspin 270 power supply:
Topspin-270# show diagnostic fru-error
================================================================================
Fru-Error
================================================================================
fru-slot fru-error
--------------------------------------------------------------------------------
card(1) _FRU_POWER_CONTROLLER_CONFIG_ERR
fan(1) none
fan(2) none
power-supply(1) none
Table 6-1: Topspin 270 Baseboard Errors
Error Number Description
1 Summit Power Controller Configuration Error
2 I2C Communication Error
3Serial EEPROM Error
4 DiskOnChip Error
5 Memory Error
6 March SSO Error
7 Realtime Clock Error
8 Fan Error
9FPGA Error
10 Summit High Temp Error
12 Summit High Current Error
14 Summit Voltage Out of Range Error
16 Firmware Error on the switch chip
17 Bus error on sw itch chip
18 ID Module Error
19 Management Module Error
Table 6-2: Topspin 270 Power Supply Errors
Error Number Description
1 Power Supply DC Fail Error