Cisco Systems SN 5428-2 manual Database, Webserver2000, 1 Target-and-LUN Mapping Example

Models: SN 5428-2

1 28
Download 28 pages 33.75 Kb
Page 7
Image 7
Table 1-1 Target-and-LUN Mapping Example

Chapter 1 Before Configuring SN 5428-2 Storage Router Software

SCSI Routing Overview

If the LUN is available, it is made available as an iSCSI LUN and numbered with the iSCSI LUN number specified. For example, if an iSCSI target and iSCSI LUN specified as Database, LUN 9 were mapped to the physical storage address, WWPN 3100112233445566, LUN 12, then LUN 12 would be available as one iSCSI LUN. An iSCSI driver would see the iSCSI target named Database, with one iSCSI LUN identified as LUN 9. The iSCSI LUN would appear as one storage device to a host. (See Table 1-1.)

Table 1-1 Target-and-LUN Mapping Example

Apparent to Host as

iSCSI Target

iSCSI LUN

Physical Storage

Physical LUN

Local Disk

Name

Available

Address

Available

 

 

 

 

 

Local Disk (D:)

Database

LUN 9

WWPN

LUN 12

 

 

 

3100112233445566

 

 

 

 

 

 

Apparent as one

Database

iSCSI LUN is

Specifies the storage

The LUN number

locally attached

appears as one

numbered as

address of a storage

is specified as the

storage device.

controller with

specified and

controller.

only LUN to be

 

one LUN

can be different

 

mapped.

 

available.

than the

 

 

 

 

physical LUN

 

 

 

 

number.

 

 

 

 

 

 

 

With target-only mapping, an iSCSI target name is specified and mapped to the physical storage address of a storage controller only; a WWPN. Any LUNs that are available in the storage controller are made available as iSCSI LUNs and are numbered the same as the LUNs in the storage controller. For example, if an iSCSI target specified as Webserver2000 were mapped to the physical storage address WWPN 3100112233445577, and LUNs 0 through 2 were available in that controller, those LUNs would become available as three iSCSI LUNs. An iSCSI driver would see the iSCSI target named Webserver2000 as a controller with three iSCSI LUNs identified as LUN 0, LUN 1, and LUN 2. Each iSCSI LUN would appear as a separate storage device to a host. (See Table 1-2.)

Table 1-2 Target-only Mapping Example

Apparent to Host as

iSCSI Target

iSCSI LUNs

Physical Storage

Physical LUNs

Local Disk

Name

Available

Address

Available

 

 

 

 

 

Local Disk (D:)

Webserver2000

LUN 0

WWPN

LUN 0

 

 

 

3100112233445577

 

 

 

 

 

 

Local Disk (E:)

Webserver2000

LUN 1

WWPN

LUN 1

 

 

 

3100112233445577

 

 

 

 

 

 

Local Disk (F:)

Webserver2000

LUN 2

WWPN

LUN 2

 

 

 

3100112233445577

 

 

 

 

 

 

Apparent as three

Webserver2000

iSCSI LUNs

Specifies the storage

LUNs 0, 1, and 2

locally attached

appears as one

are numbered

address of a storage

are available for

storage devices.

controller with

the same as

controller.

mapping.

 

LUNs 0, 1, and

physical LUNs.

 

 

 

2 available.

 

 

 

 

 

 

 

 

Cisco SN 5428-2 Storage Router Software Configuration Guide

 

OL-4691-01

1-7

 

 

 

Page 7
Image 7
Cisco Systems SN 5428-2 manual Database, Webserver2000, 1 Target-and-LUN Mapping Example, 2 Target-only Mapping Example