Cisco Systems SN 5428-2 manual 1-14, Intelligent Storage Array and, SCSI Routing, Drive LUN

Models: SN 5428-2

1 28
Download 28 pages 33.75 Kb
Page 14
Image 14
Intelligent Storage Array and

Chapter 1 Before Configuring SN 5428-2 Storage Router Software

Transparent SCSI Routing Overview

to it, with each host having a WWPN. Table 1-5shows the correlation between the IP hosts, the Gigabit Ethernet IP address of the SCSI routing instance, storage device mapping, and IP-host-to-FC-address (WWPN) mapping.

Note The purpose of Figure 1-13and Table 1-5is only to illustrate the concept of storage mapping, FC address mapping, and access control. The IP addresses and WWPNs will vary according to each site. In addition, the figure and the table exclude any additional SN 5428-2 Storage Routers that could be configured for multiple paths between hosts and storage devices.

Figure 1-13 Transparent SCSI Routing Storage Mapping and Access Control Concept

IP host A

Cisco SN 5428-2

Storage

 

with IP address

IP host B

10.1.2.3

array

 

 

IP

FC

 

IP host C

SN 5428-2 presents IP hosts as

FC hosts with WWPNs:

IP host A = WWPN 201000023D000100 IP host B = WWPN 201000023D000101 IP host C = WWPN 201000023D000102

WWPN 3100112233445566

and its LUNs accessible by IP host A

SCSI RoutingDrive (LUN)1-14Manual background WWPN 3100112233445577

and its LUNs accessible by IP host B

WWPN 3100112233445588

and its LUNs accessible by IP host C

85731

Table 1-5 Transparent SCSI Routing Storage Mapping and Access Control Concept

 

 

 

 

 

 

 

Storage Devices

Via GbE IP

Mapped To Storage

 

Hosts Allowed Access by

Apparent to Host as

Address of

 

 

 

 

Intelligent Storage Array and

Locally Attached

SCSI Routing

 

 

SN 5428-2 Authentication

Devices

Instance

WWPN

Drive (LUN)

 

 

 

 

 

Host A: apparent to storage

Local Disk (D:)

10.1.2.3

3100112233445566

0

array as FC host with WWPN

 

 

 

 

Local Disk (E:)

10.1.2.3

3100112233445566

1

201000023D000100

 

 

 

 

Local Disk (F:)

10.1.2.3

3100112233445566

2

 

 

 

 

 

 

Host B: apparent to storage

Local Disk (D:)

10.1.2.3

3100112233445577

0

array as FC host with WWPN

 

 

 

 

Local Disk (E:)

10.1.2.3

3100112233445577

1

201000023D000101

 

 

 

 

 

 

 

 

 

Host C: apparent to storage

Local Disk (D:)

10.1.2.3

3100112233445588

0

array as FC host with WWPN

 

 

 

 

Local Disk (E:)

10.1.2.3

3100112233445588

1

201000023D000102

 

 

 

 

Local Disk (F:)

10.1.2.3

3100112233445588

2

 

 

 

 

 

 

 

Local Disk (G:)

10.1.2.3

3100112233445588

3

 

 

 

 

 

Cisco SN 5428-2 Storage Router Software Configuration Guide

1-14

OL-4691-01

 

 

Page 14
Image 14
Cisco Systems SN 5428-2 manual 1-14, Intelligent Storage Array and, SCSI Routing, Drive LUN