Cisco Systems UC560T1E1K9 manual Power Specifications for the Cisco UC

Models: UC560T1E1K9

1 12
Download 12 pages 15.23 Kb
Page 10
Image 10

Table 13. Power Specifications for the Cisco UC 560

Feature

AC input voltage AC input frequency AC input current

AC input surge current Power dissipation (AC)

Description

100 to 240V AC

50 to 60 Hz

3 to 1.5A (100 to 240V)

30 to 60A (100 to 240V)

67W

Table 14.

Environmental Specifications for the Cisco UC 560

 

 

 

Feature

 

Description

 

 

Operating temperature

32° to 104°F

 

 

Operating humidity

10% to 85% noncondensing, operating

 

 

5% to 95% noncondensing, nonoperating

Nonoperating temperature

4° to 149°F (-20° to 65°C)

 

 

Operation altitude

104°F (40°C) at sea level

 

 

87.8°F (31°C) at 6000 ft (1800 m)

 

 

77°F (25°C) at 10,000 ft (3000 m)

 

 

34.7°F (1.5°C) per 1000 ft

Dimension

 

3.5 x 17.25 x 13.78 in.

(H x W x D)

 

(8.89 x 43.82 x 35.00 cm)

 

 

Power supply dimensions (H x W x D)

Internal power supply

 

 

 

Rack height

 

2 rack units (RU)

 

 

Weight (fully configured)

14.5 lb (6.58 kg)

 

 

Noise level (minimum and maximum)

Normal operating temperature:

 

 

< 81°F (27°C): 37 dBA

 

 

< 93°F (34°C): 44 dBA

 

 

54 dBA (at maximum fan speed)

Table 15.

Regulatory Compliance for the Cisco UC 560

Category

Safety

Immunity

Compliance

IEC 60950-1

AS/NZS 60950.1

CAN/CSA-C22.2 No. 60950-1

EN 60950-1

UL 60950-1

EN 55024

EN 300-386

EN 61000-6-2

EN 50082-1

EN 55024 (CISPR 24)

© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.

Page 10 of 12

Page 10
Image 10
Cisco Systems UC560T1E1K9 manual Power Specifications for the Cisco UC, Environmental Specifications for the Cisco UC