Appendix D
CGI Commands
Download Logs
Method: GET
URL:http://<ip>/adm/log.cgi
Return:
HTTP/1.0 200 OK \r\n
…
…
<log data>
Motion Detection Commands
You can configure the motion detection sensitivity area to be either the entire screen or up to three specific areas. Each area can have its own name and threshold setting. Once the moving indicators exceed the
This is the definition of the sensitivity area coordinates on a 640x480 resolution image.
The home (0, 0) position is located at the
(0,0)
640
480
(639,479)
The
(X1, Y1) = (0,0)
(X2, Y2) = (639,479)
Whatever the current streaming resolution is, the replied coordinate always maps to the 640x480 scale.
Get Motion Detection Settings
Method: GET
URL:http://<IP>/adm/get_group.cgi?group=MOTION
(Please refer to Get Group Parameters command.)
Parameter
Value and description
group
Motion
(Required) This notifies the CGI that the request is for “motion detection” group.