Internal connections of the electrical heating

s

H

Heating

3x220V

R5

3x380V

R5

 

 

 

 

 

 

27kW

3x3kW

s

LC1D1810

H

LC1D0901

 

3x3kW

s

LC1D1810

H

LC1D0901

 

3x3kW

s

LC1D1810

H

LC1D0901

 

 

 

 

 

 

36kW

3x4kW

------

------

s

LC1D1810

 

3x4kW

------

------

s

LC1D1810

 

3x4kW

------

------

s

LC1D1810

 

 

 

 

 

 

B = Black

Bu = Blue

Br = Brown

R = Red

Gy = Grey

W = White

Tilt switch

1/2

1/2

1/3

Window

Probe

The tilt switch is mounted on the solid part of the machine. There is a window around the probe of the tilt switch that is mounted on the movable part of the machine. When the machine goes out of balance by overloading or uneven distribution of the linen, the tilt switch will interrupt this action to prevent damage to the machine.

Important

To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the tilt window (when machine drum is empty).