Installation
Dimensions and Specifications
Laundry Press |
| Net Weights |
| Supply Requirements |
| |||
|
|
|
|
|
|
|
| |
|
| Weight | Air |
| Steam (Max. Pressure | |||
|
|
| 115 psig [7.9 bar]) | |||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Model |
|
|
| cu. ft. (cu. m) |
| BHP (kw) |
|
|
|
|
|
| free air/cycle |
|
| lbs. (kg) | |
| lbs. |
| kg |
| @ 115 psig |
| ||
|
| @ 80 psig |
|
| conds/hr | |||
|
|
|
|
| (7.9 bar) |
| ||
|
|
|
| (5.5 bar) |
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
LDCC | 370 |
| 168 | 1 (.03) |
| .75 (7.35) |
| 26 (12) |
|
|
|
|
|
|
|
|
|
LDBB | 370 |
| 168 | 1 (.03) |
| .75 (7.35) |
| 26 (12) |
|
|
|
|
|
|
|
|
|
Table 1
Electrical Requirements
(Presses With Timers Only)
NOTE: Presses without timers do not require electric hook-up.
115 Volt, 230 Volt/60 Hertz/1 Phase, (0.50, 0.25) full load amps
110 Volt, 220 Volt/50 Hertz/1 Phase, (0.50, 0.25) full load amps
Electrical Data
Nominal Voltage* | 115 | 230 | 110 | 220 | |
|
|
|
|
| |
Frequency/Phase | 60/1 | 60/1 | 50/1 | 50/1 | |
|
|
|
|
| |
Rated Amperes** | 0.50 | 0.25 | 0.50 | 0.25 | |
|
|
|
|
| |
Average Running Amperes | 0.31 | 0.16 | 0.31 | 0.16 | |
|
|
|
|
| |
Quantity Electrical Connections | 2 + grd | 2 + grd | 2 + grd | 2 + grd | |
|
|
|
|
|
|
* | The voltages listed are rated machine voltages. The currents listed are rated for system voltage ranges of 110 – 220 and 220 – 240. | ||||
** | Rated Amperes are to be used to determine incoming conductor size and | ||||
| accordance with the 1981 NATIONAL ELECTRIC CODE, Sections |
|
| ||
|
|
|
|
|
|
Table 2
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | AJ1031 |