Installation

Required Materials

NOTE: Applicable codes, ordinances, specifications and/or other governing data related to installation must be complied with. The materials listed in Table 4 MAY or MAY NOT conform to these requirements.

Quantity

Description

Source

 

 

 

1

Models with timer ONLY. Lockout type fused disconnect switch suitable for

Local

 

electric service connected to press (refer to wiring schematic in control box). Not

 

 

required if circuit breaker is used.

 

 

 

 

As required

Models with timer ONLY. Wire of suitable size, type and length to connect

Local

 

electric service to press (refer to wiring schematic in control box).

 

 

 

 

As required

Models with timer ONLY. Flexible conduit and connections to encase wires and

Local

 

make connections (refer to wiring schematic in control box).

 

 

 

 

2

Steam trap and check valve, or combination steam trap/check valve sized for buck

Local

 

and head steam return lines and steam consumption.

 

 

 

 

3

Ball shut-off valves sized for steam supply and return lines.

Local

 

 

 

1

Ball shut-off valve sized for air supply line.

Local

 

 

 

4

Anchor bolts.

Local

 

 

 

As required

Pipe, couplings, unions, flanges, etc., to connect steam supply and return lines and

Local

 

air supply line to press. Wall thickness of pipe and tubing must be in compliance

 

 

with recommendations by compressor and boiler manufacturers and local code

 

 

(refer to sections on Connecting Steam Supply and Returns and Connecting Air

 

 

Supply).

 

 

 

 

 

Table 4

 

Receiving Inspection

Press is shipped assembled and enclosed in a wood slat crate. Upon delivery, inspect crate and contents for shipping damage. If crate or cover is damaged, or signs of possible damage are evident, have carrier note condition on shipping papers BEFORE shipping receipt is signed, or advise carrier of condition when discovered.

Remove protective cover and check items received against items listed on packing list. If any item is damaged or missing, a written claim should be filed with carrier as soon as possible.

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

AJ1031