Installation
Required MaterialsNOTE: Applicable codes, ordinances, specifications and/or other governing data related to installation must be complied with. The materials listed in Table 4 MAY or MAY NOT conform to these requirements.
Quantity | Description | Source |
|
|
|
1 | Models with timer ONLY. Lockout type fused disconnect switch suitable for | Local |
| electric service connected to press (refer to wiring schematic in control box). Not |
|
| required if circuit breaker is used. |
|
|
|
|
As required | Models with timer ONLY. Wire of suitable size, type and length to connect | Local |
| electric service to press (refer to wiring schematic in control box). |
|
|
|
|
As required | Models with timer ONLY. Flexible conduit and connections to encase wires and | Local |
| make connections (refer to wiring schematic in control box). |
|
|
|
|
2 | Steam trap and check valve, or combination steam trap/check valve sized for buck | Local |
| and head steam return lines and steam consumption. |
|
|
|
|
3 | Ball | Local |
|
|
|
1 | Ball | Local |
|
|
|
4 | Anchor bolts. | Local |
|
|
|
As required | Pipe, couplings, unions, flanges, etc., to connect steam supply and return lines and | Local |
| air supply line to press. Wall thickness of pipe and tubing must be in compliance |
|
| with recommendations by compressor and boiler manufacturers and local code |
|
| (refer to sections on Connecting Steam Supply and Returns and Connecting Air |
|
| Supply). |
|
|
|
|
| Table 4 |
|
Press is shipped assembled and enclosed in a wood slat crate. Upon delivery, inspect crate and contents for shipping damage. If crate or cover is damaged, or signs of possible damage are evident, have carrier note condition on shipping papers BEFORE shipping receipt is signed, or advise carrier of condition when discovered.
Remove protective cover and check items received against items listed on packing list. If any item is damaged or missing, a written claim should be filed with carrier as soon as possible.
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | AJ1031 |