iDP-3210 User’s Manual idp-3210 User's Manual

6.1.3I/O SIGNALS

(1)Input Signals to the Printer

DATA : 8-bit parallel signal (positive logic)

STB : Strobe signal to read 8-bit data (negative logic)

RESET : Signal to reset the entire printer (negative logic) 1m sec or more

(2)Output Signals from Printer

ACK : An 8 bit data request signal. Pulse signal output at the end of the BUSY signal. (negative logic)

BUSY : The signal to indicate BUSY state of the printer. Input new data for "LOW". (positive logic)

FAULT : The signal which is made "LOW" when the printer is in alarm state. All the control circuits inside the printer are stopped at this time.(negative logic)

PE

: The signal which is output when paper runs out or goes scarce. (positive logic)

Drawer Switch Output: With the switch open, this signal goes "HIGH". When shorting, this goes "LOW".

(3)Power supply

+5 V DC

: This is 5V pulled up by a 3.3kΩ resistor.

GND

: This is the common ground for the circuit.

34/67 CITIZEN

Page 34
Image 34
Citizen iDP-3210, Line Thermal Printer user manual 34/67 Citizen, 3 I/O Signals