Citizen Line Thermal Printer, iDP-3210 user manual 39/67 Citizen

Models: Line Thermal Printer iDP-3210

1 67
Download 67 pages 54.45 Kb
Page 39
Image 39

iDP-3210 User’s Manual idp-3210 User's Manual

6.2.3I/O SIGNALS

(1)RD

Serial receiving data signal. On occurrence of framing error, overrun error, or parity error, the data is printed as "?".

(2) DTR

When this signal is READY, write data or a command. When they are written in BUSY, overrun error is occurred and data is ignored. Even during printing, data can be loaded in the input buffer. Further, BUSY can take place on supply of power, during test printing, during on-line, or on resetting.

(3) TD

When, while in data reception, the input buffer on the printer side has only 128 bytes .or less left,DC3 (13H) data reception impossible signals are output. When the input buffer has 256 bytes

left, DC1 (11H) data reception possible signals are output to the host. When DTR/DSR control having been selected in status information transmission, it is first confirmed that DSR is "space" and data is sent. When DTR/DSR control has not been selected, DSR is ignored and data is transmitted.

(4) FG

Case GND

(5) GND

Common GND on the circuit.

39/67 CITIZEN

Page 39
Image 39
Citizen Line Thermal Printer, iDP-3210 user manual 39/67 Citizen