iDP3410 User's Manual

ESC "D" [n]k NUL

[Function]

Setting the Horizontal tab position

[Code]

<1B>H <44>H [n]k <00>H

[Range]

1 n 255

 

0 k 32

[Outline]

This command sets the horizontal tab position. n denotes the number of columns from the

 

head of the line to the horizontal tab setting position and equals the set column position -

 

1. k denotes the number of horizontal tab positions to be set. The tab position is set at the

 

character width × n from the head of the line. The character width at this time includes the

 

space to the right of the character; it will be double the normal character width if the

 

double width characters are selected.

 

The data <n>k denoting the set position is entered in the ascending order and ends with

 

<00>H. ESC D NUL clears all the set tab positions. HT is ignored after clearing.

[Caution]

If the data <n>k is equal to or smaller than the preceding data <n>k - 1, it is assumed that

 

horizontal tab setting has been completed. If this is the case, the subsequent data will be

 

processed as normal data.

 

Up to 16 horizontal tabs can be set. The data beyond this limit are processed as normal

 

ones. If the data <n>k exceeds the one-line print range, set the "set column position =

 

maximum print columns + 1."

 

Even if the character width is changed after setting the horizontal tab position, the latter

 

will not change.

[Default]

7×9 font, every 8 characters (9th, 17th, 25th column, and so on)

91

CITIZEN

Page 105
Image 105
Citizen Systems pmn manual ESC D nk NUL