iDP3410 User's Manual
11.DRAWER
(1)Drawer
Parallel Interface
Serial Interface
(2)Electrical characteristics
1)Drive voltage: 24 V DC
2)Drive current: 0.8 A at maximum(Within 510 ms)
3) Switch signal: Signal level | "L" = 0 | ∼ 0.5 V |
| "H" = 3 | ∼ 5 V |
11.2 Connector's Pin Configuration
No. | Signal |
| Function |
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | FG | Frame Ground |
|
|
|
|
|
|
|
|
|
|
|
|
| |
2 | DRAWER 1 | Drawer 1 drive signal |
|
|
|
|
|
|
|
|
|
|
|
|
| |
3 | DRSW | Drawer switch input |
|
|
|
|
|
|
|
|
|
|
|
|
| |
4 | VDR | Drawer drive power |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
5 | DRAWER 2 | Drawer 2 drive signal |
|
|
|
|
|
|
|
|
|
|
|
|
| |
6 | GND | Common ground on the circuit |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Connector used | : | ||||||||||||||
| Applicable connector | : |
CAUTION : ∙ No output is made while printing.
∙The drawers 1 and 2 cannot be driven simultaneously.
∙A solenoid used for the drawer should be of 36Ω or more. An output current should be kept below 0.8 A. Use beyond this limit cannot be assured.
∙This connector cannot be connected to a telephone line. Do not connect other than the solenoid.
11.3Drive Circuit
31 | CITIZEN |