PRODUCT SPECS

Problem

Audio lacks punch.

Solution

Speakers wired incorrectly, which causes cancellation of bass frequencies. Check polarity of wires from amplifier to each speaker as defined by the system design.

Problem

Amplifier fuse keeps blowing.

Solution

Incorrect wiring or short circuit. Review Installation and check all wiring connections.

Problem

Whining or ticking noise in the audio with engine on.

Solution

Amplifier is picking up alternator noise or radiated noise. Turn down input gain; move audio cables away from power wires. Check power and ground connections on amplifier; install an in-line noise filter on source unit’s power wire; check alternator and/or voltage regulator; test for weak battery or add water to battery

PRODUCT SPECS

 

APX400.4M

Frequency Response

20Hz ~ 20kHz

Signal Noise Ratio

>95db

THD

.05% all channels driven

Input Sensitivity Low Level

250mV ~ 2.5V

Input Sensitivity Speaker Level

500mV ~ 5V

Max. Power Output

380W (190 x 2)

Cont. Power Output

200W (50W x4) @.08% THD

2-Ohm Stereo Output

90 x 4 @ .8% THD

Bridged Power

190 x 2 @ .8% THD

Dimensions

2 1/8”H x 8 1/4”W x 12” L

Current Consumption @ Max Power Output

46A @ 380 Watts