9. TROUBLESHOOTING

 

Problem

Cause

Measure

 

Power does not

Fuse is blown.

Replace with a fuse of the same amperage. If the

 

turn on.

 

fuse blows again, consult your store of purchase.

 

(No sound is

 

 

 

 

 

 

 

 

 

 

produced.)

Incorrect wiring.

Consult your store of purchase.

 

 

 

 

 

 

 

No sound output

Amplifier turn-on lead is

Turn the unit off and check each wire for a possible

 

when operating

shorted to ground or

short. If the amplifier turn-on lead shorts out, cover it

 

the unit with

excessive current is required.

with insulation such as tape.

 

amplifiers.

 

 

 

 

 

 

 

 

 

 

 

Nothing happens

The microprocessor has

Turn off the power, then

 

when buttons are

malfunctioned due to noise,

press the [RELEASE]

General

pressed.

etc.

button and remove the

 

 

DCP.

 

 

 

Press the reset button for

 

 

 

about 2 seconds with a thin

 

 

 

rod.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset button

 

 

 

 

 

 

 

Display is not

DCP or source unit

Wipe the dirt off with a soft cloth moistened with

 

accurate

connectors are dirty.

cleaning alcohol.

 

 

 

 

 

 

 

No audio.

The speaker protection

1. Check the speaker connection.

 

 

circuit is operating.

2. Turn down sound volume. Function can also be

 

 

 

restored by turning the power off and on again.

 

 

 

3. If the sound is muted again, consult your store of

 

 

 

purchase.

 

 

 

 

 

 

 

Compact disc

Another compact disc is

Eject the compact disc before loading the new one.

 

cannot be loaded.

already loaded.

 

 

 

 

 

 

 

 

 

 

Sound skips or is

Compact disc is dirty.

Clean the compact disc with a soft cloth.

CD

noisy.

 

 

 

 

 

 

 

 

 

 

Compact disc is heavily

Replace with a compact disc with no scratches.

 

 

 

 

scratched or warped.

 

 

 

 

 

 

 

 

Sound is bad

Water droplets may form on

Let dry for about 1 hour with the power on.

 

directly after

the internal lens.

 

 

 

 

power is turned

 

 

 

 

 

on.

 

 

 

 

 

Source selection

The microprocessor has not

Perform a system check.

CeNET

does not

stored the proper CeNET

See “Operations Common to Each Mode”,

recognize CeNET

information.

performing a system check section.

 

source

 

 

 

 

 

 

 

 

 

 

connection.

The CeNET cable is not

Ensure the CeNET cables are properly connected.

 

 

connected properly.

 

 

 

 

 

 

 

 

 

English