Operator’s Manual |
7.On all gas,
8.On all steamcoil units, the incoming steam pressure must be
9.Check that the drain lines meet installation requirements specified in installation paragraph 4
WARNING
INJURY TP PERSONNEL AND EQUIPMENT DAMAGE may result from an improper installation.
10.After completing checks 1 through 9, correct any deficiencies refer to the
11.Check to ensure that the water in the boiler sight gauge glass automatically stays about 1/3 full when boiler is started up and operated.
12.Check to ensure that the steam pressure gauge registers 10 psi. The steam pressure is factory- adjusted to 10 psi
Factory setting may shift due to shaking in transit and resetting will be required after installation. Proper ad- justments and maintenance procedures am detailed on a separate data sheet entitled "Steam Pressure Adjust- ments." Adjustments should be made only by qualified service personnel- the factory pressure settings shown in the accompanying chart should never be exceeded.
GAUGE PRESSURE READING WITH NO STEAM FLOW* (STATIC PRESSURE)
Operating Pressure Switch | 10 psi |
High Limit Safety Pressure Switch | 15 psi |
|
|
Operating Pressure Switch | 10 psi |
High Limit Safety Pressure Switch | 15 psi |
Steam Supply Pressure Range | |
|
|
Steamer Pressure Reducing Valve | 10 psi |
Steam Supply Pressure Range | |
** With or without kettle |
|
______________________________________________________________________________ 6