Look to see if the generator has a buildup of scale greater than the thickness of a business card or if the top is beginning to peel off in layers. If either one of these condi- tions is present, the generator needs to be chemically descaled by your CLEVELAND AUTHORIZED SERVICE

AGENCY.

a. Inspect more frequently in areas where the water con- ditions do not meet the Water Quality Requirements.

1.Change the boiler gasket every time you open the boiler for liability reasons.

2.Check to see that all door fasteners are tight.

3.Check to see that all steam, water, and electrical con- nections are secure. If any are loose contact your

authorized service agency to make the REPAIRS

It is in your best interest to maintain as many preventive maintenance records as possible. When contacted by a customer or service agency the manufacturer appreciates having this information available.

The record keeping chart provided with the steam gen- erator would assist you and your service agency. It will help you record your maintenance and service history of the equipment.

If you have any questions concerning the proper installa- tion and maintenance of your CLEVELAND STEAM COOKER call the Cleveland Service Department at (216) 4814900.