Steamer won't fill with the handle in the on position

PROBLEM:

24CGA6

24CGA10.2

Steamer won't fill with the handle in the on position

Steamer won't

fill

Is there power to the steamer?

Yes

Is there water to

the steamer?

Yes

Is there 120 VAC

between the

terminals H and N on the watr level board?

Yes

Is there 120 VAC between terminals Fill and N on the water board?

Yes

No

No

No

No

Connect

power to the steamer

Supply

water to the

steamer.

Adjust or replace on/off micro switch

With the wire

removed from the HI terminal on the water level board, is there 120 VAC between terminals Fill and N?

Yes

Replace the

No

water level

board.

Adjust or

replace the on/

No

Is there 120 VAC across the coil of

Is there debris on the HI probe in the

No

Replace the

off micro switch

the fill solenoid?

Yes

probe assy?

Yes

wire to the HI

probe.

Replace the fill

solenoid.

Clean or

replace the drain valve.

No

No

Is water leaving

 

the fill solenoid?

 

Yes

Yes

Does the manual

 

drain valve close

 

completely?

 

Clean or

replace the probe assy.