Cleveland Range PROBLEM 24CGA6, 24CGA10.2, Electronic timer displays PAUS and wont count down

Models: 24CGA10.2

1 23
Download 23 pages 49.52 Kb
Page 22
Image 22
PROBLEM:

PROBLEM:

24CGA6, 24CGA10.2

Electronic timer displays "PAUS" and won't count down

START

Is steam heating the cooking cabinetabove 192 degrees (the set temp of the thermo-switch)?

Yes

See

No Electronic timer displays "PAUS" and won't count down Steamer won't steam

Replace the

Yes

Does the timer count down when

No

Replace the

thermo-switch

the thermo-switch

is bypassed?

electronic timer

PROBLEM:

24CGA6, 24CGA10.2

Steam leaks around the door.

START

Is COLD water supplied to the steamer?

Yes

Is the door gasket

physically damaged?

Yes

Turn over the gasket or replace it.

No

No

Supply cold water (35-60 PSI) to the steamer.

Is the door out of

alignment?

Yes

Replace the door bearings and pins.

No

Is the drain obstructed?

Yes

Remove the obstruction

No

Is there 120 VAC

 

 

 

Replace the

across the coil of

No

 

wiring to the

the condensate

 

condensate

 

 

 

solenoid?

 

 

 

solenoid.

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Replace the

Is the solenoid

 

 

 

No

 

 

condensate

opening?

 

 

 

 

solenoid.

 

 

 

 

 

 

 

 

 

Yes

Replace the

condensate spray

nozzle