Each Compartment has capacity for:

Each Compartment has capacity for:

• Five, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans.

WATER QUALITY

REQUIREMENTS

The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.

ABDEC

 

 

GAS

 

 

ELECTRIC

C COLD WATER

 

CLEARANCE

D DRAINAGE

 

 

1 ⁄4˝ IPS line size,⁄4˝ (13mm) connection

120V-1Phase, 60 Hz.

35 psi minimum

 

 

 

1 ⁄2˝ dia.

 

 

 

RIGHT = 3˝ operating,

 

 

1

3

 

 

 

 

 

Right - 3”, Left - 3”,

 

1

 

 

 

 

 

 

 

 

 

Rear -3”

 

 

 

 

NATURAL

PROPANE

BTU

2 Blowers & Controls

60 psi maximum

 

12˝ if adjoining wall or

 

Do not connect other

 

 

 

 

 

 

 

 

 

(12” on control side if adjoining

 

 

 

 

Piping 34˝ N.P.T.

Piping34˝ N.P.T.

 

 

 

 

 

 

 

72,000 each

150 watts each

 

 

wall or equipmentLEFT =is over30”

 

units to this drain

 

 

Supply pressure

Supply pressure

Generator,

 

One (E) 1/4" dia.

 

high for service access)

 

 

 

 

 

 

REAR = 3˝

 

 

 

 

4.50˝ W.C. Min.

11.00˝ W.C. Min.

144,000 total

 

NPT for Generator

 

Allow 6˝ space min.

 

Drain must be vented

 

 

 

 

 

 

 

 

 

Contact factory

 

 

 

 

14.00˝ W.C. Max.

14.00˝ W.C. Max.

 

 

 

 

 

for variances to

 

 

 

 

 

 

 

 

 

from rear and sides

 

 

 

 

 

 

 

 

 

One (D) 1/4" dia

 

clearances.

 

Do not use PVC pipe

 

 

 

 

 

 

 

 

when located near

 

 

 

Manufacturer must be notified if unit will

 

 

 

NPT for Condenser

 

combustible walls

 

 

 

 

be used above 2,000 feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).

(NOT TO SCALE) SECT. IV PAGE 14 0402

Litho in U.S.A.

Page 12
Image 12
Cleveland Range 24CGA10.2 manual Each Compartment has capacity for, Five, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans