PROBLEM:

PROBLEM:

 

 

 

 

 

 

 

Steam generator

 

 

Is the red light on?

No

24CGA6

 

won't ignite

 

 

 

 

 

 

 

24CGA10.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steamer won't

 

 

 

 

Yes

ignite

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there power to

the steamer?

Yes

No

Connect power to the steamer

Clean or

replace the 24CGA6 No probe assy.

 

See

 

 

 

 

 

Is there water in

 

Steamer won't

 

 

No

the sight glass?

 

fill

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

Is there 120 VAC

 

 

 

 

 

 

 

between Heat and N

 

 

 

 

 

 

 

terminals on the water

 

 

 

 

 

 

Is there 120 VAC

level board with a

 

 

No

between the

jumper between

 

 

 

 

 

 

terminals Heat and

terminal XL and C?

 

 

 

 

 

 

N on the water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

level board with

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

the the low probe

 

 

 

 

 

submerged?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yes

 

 

 

 

 

 

 

 

 

Replace water

 

 

 

 

 

Is there 120 VAC

level board.

 

 

 

 

 

across the primary

 

 

 

 

 

 

 

 

of the 24 VAC

 

 

 

 

 

 

 

 

ignition

 

 

 

 

 

 

 

 

transformer?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

Replace the

 

 

 

 

 

Is there 24 VAC to

No

 

 

 

the secondary of

transformer

 

 

 

the ignition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transformer?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

Replace the wires

 

 

 

 

 

Is there 24 VAC to

No

 

 

 

the ignition

to the ignition

 

 

 

 

 

 

 

 

module?

module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

No

Yes

Adjust or replace the on/off micro switch

Replace the high limit

Does the pilot gas valve open when the 24 VAC is applied?

Yes

Is spark generated

at the igniter?

Yes

Is there at least

1.0micro amps DC at the burner

ground terminal on

the ignition module?

No

No

No

Replace the gas valve.

Replace the igniter and wire

Is the pilot flame

blue and

enveloping the igniter?

Yes

Replace the

No

pilot assy

Replace the

No

ignition module

No

Supply gas to

Is there spark from the module until the 90-second lock out?

Yes

Is there 24 VAC to the pilot coil on the gas valve until the 90-second lock out?

Yes

Yes

Replace the

ignition module

Replace the ground wire

the steamer

No

Does the steamer have gas supplied?