PROBLEM:

PROBLEM:

24CGA6

24CGA10.2

Steamer won't

steam with handle

in on position

Steamer won't

steam

See

Steamer won't Steamer won't No fill.

See

Steamer won't Steamer won't  No fill. No ignite

Is the red light on? Steamer won't  No ignite

Yes

Is there water in the sight glass?

Yes

Has the pilot ignited?

Yes

No

Is there power to the steamer?

Yes

Adjust or replace the on/off micro switch

No

Connect power

to steamer.

 

Replace the

wiring to the No switch

Replace the

No

switch

 

Is there power to the Timed/Manual switch?

Yes

Is there power

from the Timed/ Manual switch?

Yes

Does the steamer

steam with the

door switch bypassed?

Yes

Replace the door switch

No

No

Does the steamer steam in manual mode?

Yes

Replace the timer

Is there 120 VAC to the R2 relay?

Yes

Is the fan turning?

Yes

Is there 24 VAC to the main coil of the gas valve?

No

No

No

Replace the wiring to relay

Is there 120 VAC

to the fan?

Yes

Replace the fan

Check the

No

R1 relay

Yes

Replace the

gas valve?

Does the coil to

the main gas valve get 24 VAC when the fan prover switch is bypassed?

Yes

Replace the the fan prover switch.

Replace the R2

No

relay.

Page 19
Image 19
Cleveland Range manual PROBLEM 24CGA6 24CGA10.2, Steamer wont steam with handle in on position, Steamer wont No fill