Cleveland Range IA-MKDL-100-CC Preventive Maintenance, COOK/CHILL MIXER & PASTA KETTLES continued

Models: IA-MKDL-200-CC IA-MKDL-150-CC IA-MKDL-100-CC IA-MKDL-60-CC IA-MKDL-300-CC

1 37
Download 37 pages 36.29 Kb
Page 32
Image 32
COOK/CHILL MIXER & PASTA KETTLES (continued)

_______________________________________________________________________

_

PREVENTIVE

MAINTENANCE

COOK/CHILL MIXER & PASTA KETTLES (continued)

E.SAFETY VALVE Weekly

-Check for leakage

-Steam pressure 65 psi. max.

-Safety set at 100 psi.

F.LEAKS Weekly

-Check for leaks of any type ( water - steam - hydraulic )

( Leaks take away from performance and will lead to costly repair )

G.Control Panels

Weekly

- Signs of water damage

- Check operation of all controls

- Water meter operation

- Temp read outs

- Temp charting

- Temp controlling

- RTD adjustments

- Mixer operation & speed control

- Gentle heat operation

- product valve operation

Page 32
Image 32
Cleveland Range IA-MKDL-100-CC Preventive Maintenance, COOK/CHILL MIXER & PASTA KETTLES continued, E.SAFETY VALVE Weekly