STEAM REQUIREMENTS FOR KETTLES
Kettle Cap. | Kettle |
| 25 psi Steam 265°F |
| 40 psi Steam 287°F | 80 psi Steam 302°F | |||||||
U.S. Gal. | Dia. | Lbs./Hr. | Hp./Hr. | Lbs./Hr. | Hp./Hr. | Lbs./Hr. | Hp./Hr. | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 | 26" | 100 | 3 |
| 120 | 4 |
| 150 | 4.5 |
| |||
60 | 29.5" | 150 | 4.5 |
| 190 | 5.5 |
| 230 | 7.0 |
| |||
80 | 33" | 210 | 6.0 |
| 260 | 7.5 |
| 300 | 9.0 |
| |||
100 | 36" | 260 | 7.5 |
| 320 | 9.5 |
| 390 | 11.0 |
| |||
125 | 40" | 320 | 9.5 |
| 400 | 11.5 |
| 470 | 14.0 |
| |||
150 | 40" | 390 | 11.0 |
| 480 | 14.0 |
| 570 | 17.0 |
|
Steam requirements are maximum per hour.
If more than one unit is on the same line then add the steam usage for each one to reach a total.
STEAM PIPE SIZING
Required pipe length in feet/meters
Steam Required | 200 Ft. | 400 Ft. | 600 Ft. |
Lbs./Kg. per hour | 60 Meters | 125 Meters | 185 Meters |
100/45 Kg. | 3/4" | 1" | 1 1/4" |
200/91 Kg. | 1" | 1 1/4" | 1 1/2" |
300/136 Kg. | 1" | 1 1/4" | 1 1/2" |
400/182 Kg. | 1" | 1 1/2" | 1 3/4" |
500/227 Kg. | 1 1/4" | 1 1/2" | 1 3/4" |
700/318 Kg. | 1 1/2" | 1 3/4" | 2" |
900/409 Kg. | 1 1/2" | 1 3/4" | 2" |
NOTES:
Pipe size in inches.
Less than 50 PSI (3.4 BAR) pressure, increase pipe size by 1/4".
80 to 100 PSI (5.5 to 6.8 BAR), Decrease pipe size by 1/4".