8.On all steamcoil units, the incoming steam pressure must be 35-50 psi. Less than 35 will not effectively operate the unit. Pressure in excess of 50 psi must be reduced (with a pressure-reducing valve) to 35-50 psi.

9.Check that the drain lines meet installation requirements specified in installation paragraph 4

WARNING

INJURY TP PERSONNEL AND EQUIPMENT DAMAGE may result from an improper installation.

10.After completing checks 1 through 9, correct any deficiencies refer to the Start-Up and Pre heat instructions in the Operation section. Verify that the unit operates properly, make checks 11 and 12.

11.Check to ensure that the water in the boiler sight gauge glass automatically stays about 1/3 full when boiler is started up and operated.

12.Check to ensure that the steam pressure gauge registers 10 psi. The steam pressure is factory-adjusted to 10 psi

Factory setting may shift due to shaking in transit and resetting will be required after installation. Proper ad- justments and maintenance procedures am detailed on a separate data sheet entitled "Steam Pressure Adjust- ments." Adjustments should be made only by qualified service personnel- the factory pressure settings shown in the accompanying chart should never be exceeded.

GAUGE PRESSURE READING WITH NO STEAM FLOW* (STATIC PRESSURE) Self-Contained Steam Generator; Gas or Electric

Operating Pressure Switch

10 psi

High Limit Safety Pressure Switch

15 psi

Self-Contained Steam Coil Generator

 

Operating Pressure Switch

10 psi

High Limit Safety Pressure Switch

15psi

Steam Supply Pressure Range

35-45 psi

Direct-Connect (to House Steam Supply)

 

Steamer Pressure Reducing Valve

10 psi

Steam Supply Pressure Range

1545 psi

** With or without kettle

 