Operation
These cams were set at the factory but must be adjusted after final installation to maximize efficiency of chemical use (see section 4.1.1 Cam Adjustment.)
3.2.3. Proper Filling
The number 4 cam determines the amount the machine is automatically filled each cycle. When the number
Note: The tank must be properly filled, and the machine properly leveled, or the float switch, which prevents the heater from turning on if the level is too low, will not permit the heater to turn on.
3.2.4. Water Pump
The water pump takes in water from the drain sump and pumps it to the spray nozzles at a rate of 35 gallons per minute and a pressure at the nozzles of approximately 7 to 10 PSI. After being released through the spray arms and washing or rinsing the dishes, the water runs down the pan to the sump, through drain screen, and back to the pump.
A
3.2.5. Pump Cavitation
By listening to the normal pumping sound of the motor it can be determined if there is insufficient water in the machine, as you will hear a hesitation in the normal pumping rhythm, which is created by the air getting into the pump. Cam 4 can be adjusted to increase the amount of water that is automatically fed into the machine during a cycle (see section 4.1.1 Cam Adjustment).
MODEL | PAGE 9 |