1.2.GL-X Operational Cycle
The
Seconds: | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 |
Instant |
|
|
|
|
|
|
|
|
|
|
|
|
|
Start Relay |
|
|
|
|
|
|
|
|
|
|
|
|
|
Cam 1 |
|
|
|
|
|
|
|
|
|
|
|
| Start/Stop |
Cam 2 |
|
|
|
|
|
|
|
|
|
|
|
| Detergent |
Cam 3 |
|
|
| WASH |
|
| DRAIN |
| RINSE |
| Drain/Rack | ||
|
|
|
|
|
|
|
|
|
|
|
| Counter | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Cam 4 |
|
|
|
|
|
|
|
|
|
|
|
| Flush/Fill |
Cam 5 |
|
|
|
|
|
|
|
|
|
|
|
| Sanitizer |
Cam 6 |
|
|
|
|
|
|
|
|
|
|
|
| Rinse |
Cam 7 |
|
|
|
|
|
|
|
|
|
|
|
| Pump Motor |
Cam 8 |
|
|
|
|
|
|
|
|
|
|
|
| Heater* |
1.With the machine powered on, toggling the START switch begins a cycle.
a)Toggling the START switch energizes both the cam timer motor and the instant start relay. The instant start relay latches ON the power to the cam timer motor so that the START switch can be released a moment after it has been toggled without the cam timer motor losing power.
b)After about 2 seconds, Cam
2.Cam switch 7 controls the pump motor. The pump motor comes ON at the beginning of the operational cycle and continues to run until the end of the drain function (controlled by cam switch 3), at which time it turns off for about eight seconds allowing time for the machine to refill enough to avoid running the pump dry before the pump motor restarts and runs to the completion of the operational cycle.
MODEL | PAGE | 3 |