Cobra Electronics CPI 300 Maintaining Your, Inverter, Service, 6TROUBLESHOOTING GUIDE, Problem

Models: CPI 300

1 10
Download 10 pages 37.53 Kb
Page 7
Image 7
6TROUBLESHOOTING GUIDE

6TROUBLESHOOTING GUIDE

Problem/

Possible

Solution

Symptom

Causes

 

Maintaining Your

MAINTENANCE & SERVICE 7

• Questions can be faxed to

Inverter

773-622-2269.

 

Low output voltage

Overload

Reduce the load.

 

No output voltage

Low input

Recharge battery.

 

 

voltage

Check connections

 

 

 

and cable.

 

 

Short circuit or

Check AC wiring for short

 

 

wiring error

circuit or improper polarity.

 

 

 

 

 

No output voltage

High input

Make sure the inverter

 

and ”fault“

voltage

is connected to a

 

indicator is lit

 

12 volt battery.

Your CPI 300 requires very little maintenance to keep it operating properly. The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals. Keep vents and fans free from dust or debris.

Automated Technical Assistance is available

24 hours, 7 days a week via e-mail at: productinfo@cobra.com.

On-line answers to frequently asked questions can be found at: www.cobra.com

 

 

 

Check regulation of

 

 

 

charging system.

 

 

 

 

 

 

No output voltage

Thermal

Allow inverter to cool down

 

when load is in

shutdown

Improve ventilation—

 

excess of 300 watts

 

make sure ventilation

 

or 2.6 amperes

 

openings in the inverter

 

 

 

aren’t obstructed. Lower

 

 

 

ambient temperature.

 

 

 

 

 

 

Low battery

Poor DC wiring,

Use proper cable.

 

alarm sounds

poor battery

Ensure good connections.

 

continuously

connection

Use new battery.

Service

You can receive technical assistance with your unit through one of our customer support services:

Automated Help Desk

is available 24 hours a day, 7 days a week at 773-889-3087.

Customer Service Operators are available at

773-889-3087 Monday through Friday, 8:00 a.m. to 6:00 p.m. CST.

7

8

Page 7
Image 7
Cobra Electronics CPI 300 manual Maintaining Your, Inverter, Service, 6TROUBLESHOOTING GUIDE, Problem, Symptom